What type of starter




















It helps in providing a better starting torque. Advantages of Autotransformer Starter. Disadvantages of Autotransformer Starter. This is another common starting method used in industries for large motors. The windings of 3 phase induction motor are switched between star and delta connection to start the motor. To start the induction motor, it is connected in star using a triple pole double throw relay. When the motor accelerates, a timer relay switches the star connection of the stator windings into the delta connection , allowing the full voltage across each winding.

The motor runs at rated speed. Advantages of Star Delta Starter. Disadvantages of Star Delta Starter. The soft starter also uses the voltage reduction technique.

It uses the semiconductor switches like TRIAC to control the voltage as well as the starting current supplied to the induction motor. The conduction angle is kept at minimum to provide reduced voltage.

The voltage is increased gradually by increasing the conduction angle. Advantages of Soft Starter. Disadvantages of Soft Starter. Just like the soft starter, a Variable frequency drive VFD can vary the voltage as well as the frequency of the supplying current. It is mainly used for controlling the speed of the induction motor as it depends on the supply frequency. The AC from the supply line is converted into DC using rectifiers. It provides full control over the motor speed from 0 to rated speed.

Advantages of Variable Frequency Drive. Disadvantages of Variable Frequency Drive. How to design a solar charge controller to charge phones, laptops, etc. With complete circuit diagram and components required. To prevent this, motor starters are needed. In an induction motor, when supply is given to the stator windings, the rotating magnetic field flux and the produced flux in the rotor windings due to the back emf, causes the motor torque to increase, causing a high rotor current.

During the time between the application of electric supply to the motor and the actual acceleration of the motor to its full speed, a large amount of current is drawn by the stator from the supply. This starting current is about 5 to 6 times more than the full load current. This time duration can be for a few seconds or longer. This causes the electrical equipment to damage because of the increased voltage drop in electrical systems due to the flow of larger currents across the cable.

For this reason, a definite method of starting the motor is needed. It is the device connected in series with the motor to decrease its starting current and then increase it as the motor starts rotating gradually. It consists of a connector that acts as a switch to control the flow of current to the motor and an overload unit which measures the flow of current through the motor and controls the halting of the motor in case of large current being drawn. The current drawn by the motor can be controlled by reducing the back emf possible by reducing the supply voltage or by increasing the rotor resistance during the motor starting.

Direct Online: It consists of simple push-button as the controller. When the start button is pressed, the switch connecting the motor and the main supply is closed and the motor gets the supply current. This type of transformer can be connected to both star and delta-type motors. The secondary winding of the autotransformer is connected to each phase of the motor. Autotransformer Multiple tapings provide a fraction of the rated voltage. At the start of the motor, the relay stays at the starting point so the motor gets the voltage only in low.

The tap point providing the voltage. Rotate the relay between the tape points to increase the voltage with the speed of the motor. And finally, connect the motor with full voltage.

Compared to other voltage reduction techniques, it provides a higher voltage for a specific starting current. It has been shown to help provide better starting torque. Star Delta Starter Nose is used in industries for large-rated motors. The winding of 3 phase induction motor is converted from star to delta.

The star connection of the induction motor is connected using that triple pole double throw relay. When the motor reaches its proper speed, the timer relay acts to turn the star connection of the stator windings into a delta connection, so that each phase receives full voltage and the motor works properly.

The Soft Starter works on the same voltage reduction system as other starters. This motor uses a semiconductor switch like the TRIAC to control the voltage as well as the current supplied to the induction motor. The minimum carrying angle is kept to give this reduced voltage to the motor. The carrying angle is increased and the voltage is gradually increased.

At the maximum carrying angle, the full line voltage is applied to the induction motor and it runs at the prescribed speed. The starting current and voltage provide a slow and smooth increase in torque so that no one feels the shock, which makes the motor work smoothly, which increases the life of the machine. Variable Frequency Drive VFD Is mainly used to control the speed of the induction motor as it depends on the given supply frequency.

Converts from the supply line to DC using AC rectifiers. Gives complete control over the determined speed of the motor from start to finish. I have more than 10 years of experience with electricals. Through ElectricalGang I want to spread my knowledge with everyone else. Your email address will not be published. Save my name, email, and website in this browser for the next time I comment. Table of Contents. Type of Motor Starters 1. Stator Resistance starter 3.

The first starting type is the Full Voltage, Non-Reversing motor controller. With an FVNR motor controller, the position of the line phases is fixed, and the motor can only be operated in one rotational direction. An FVNR can be thought of as an across the line controller. This is accomplished by adding a second contactor. This reversal of two phases causes the magnetic field in the motor windings to be reversed, causing the motor to spin in the opposite direction.

Special physical safeguards are in place to prevent the damaging effect of both contactors actuating at the same time. The third type of motor starting method is called reduced voltage starting. Large motors can have a very high starting current that may be harmful to the motor or the motor controller itself. This type of motor controller limits the amount of starting current by applying a reduced voltage to the motor when it first starts. There are several ways to accomplish this, such as auto-transformer, star-delta, and soft starter.

These will be described later. The last type of motor starting method is multi-speed. Multi-speed motor controllers use solid state or transforming means to allow motors to be controlled at different speeds. Two of these methods, Variable Speed Drive and 2-speed control will be described later. Now that we have described the four major categories of the motor controller by starting method, we will now describe the six major motor starter types. Due to safety considerations, manual motor starting is limited to the motor of 10 horsepower or less.

They can be used on single or with three-phase applications. Magnetic motor starters, or direct online starters , are the most common single-speed starter type.